RFL SMX3 / 21 Page 5 of 22 Issue 1.4
User Manual
08 June 2009
5. Channel Characteristics
The maximum bandwidth that may be configured for Data Channel A (X.21) is a
function of the speed of the aggregate.
The sample rates for Aggregate Channels 2 & 3 are also a function of the aggregate
speed; thus the maximum baud rate that can be configured for Data Channels B & C
are a function of both the aggregate speed and the aggregate channel to which they
are assigned. The range of baud rate settings remains the same regardless of
aggregate speed.
Data Channel Aggregate Speed 64kbit/s 128kbit/s 192kbit/s 256kbit/s
Channel A
(X.21)
Bandwidth kbit/s
64
64 or 128
Sample Rate 16k 32k 48k 64k
Baud Rate range
(Async Mode)
1200 - 9600
Channel B or C
(V.24) assigned
to Agg. Ch 2
Baud Rate range
(Transparent Mode)
4800 9600 19200 38400
Sample Rate 8k 16k 24k 32k
Baud Rate range
(Async Mode)
1200 -
4800
1200 - 9600
Channel B or C
(V.24) assigned
to Agg. Ch 3
Baud Rate range
(Transparent Mode)
2400 4800 9600 19200
Transparent Mode is a high speed configuration for the V.24 ports particularly suited
to applications for protection relays. The end to end delay in this mode is less than
0.5s (excluding delays introduced by the comms link).